BLACK WEEKSViale −15 % · kompleti −10 % · ostalo −5 %s kodoBrezplačna dostava v Nemčiji od 200 €

Ta stran je bila prevedena samodejno in lahko vsebuje napake. Ste materni govorec? Veseli bomo vaših povratnih informacij in popravkov.Pošljite povratne informacije

The Peptide Desk The Peptide Desk
Insulin Glargin U300 (Toujeo), fotografija izdelka
Medication

Insulin Glargin U300 (Toujeo)

Medication

  • Odprema iz Nemčije

Naročilo

Cena na kos - Brezplačna dostava v Nemčiji od 200 € med Black Weeks
  • DHL s sledenjem
  • Diskretna embalaža

4.6 od 5 na Trustpilotu73 ocen

Na prvi pogled

Insulin Glargin U300 (Toujeo) v številkah

Ključni podatki iz našega leksikona.

Celoten vnos v leksikonu
Class
Long-acting basal insulinanalogue
Use
Subcutaneousonce daily, pen only
Sizes
1.5ml/450iu1 size in the shop

Za Insulin Glargin U300 (Toujeo) še ni laboratorijske analize. Glasujte zanjVse laboratorijske analize

Znanje

Vse o Insulin Glargin U300 (Toujeo)

FAQ

Pogosta vprašanja

Viri za vsak odgovor: vnos v leksikonu

Imate še vprašanje?

Pišite nam, naša ekipa vam bo pomagala.

How does U300 differ from U100?

Only the concentration: 300 instead of 100 units per millilitre, the same compound. The smaller depot releases it more evenly. In a 36-hour clamp level and effect ran flatter over 24 hours and tight glucose control lasted a median of about 30 hours, around 5 hours longer than with U100.

Why is a regular insulin syringe dangerous?

Regular insulin syringes are calibrated for U-100. With U300 solution the same mark holds three times the amount and you cannot see it. In the FDA drug database the 300 units/ml version is only listed as a prefilled injector with 1.5 or 3 ml, not as a vial.

Is Insulin Glargine U300 approved?

Yes. Drugs@FDA lists the 300 units/ml version since 25 February 2015. ChEMBL lists the compound insulin glargine with first approval in 2000. Everything here is the state of research, not a recommendation.

What did the EDITION trials show?

Same glucose control, less hypoglycaemia at night. In EDITION 1 (807 participants) 36 instead of 46 percent had night-time hypoglycaemia. The pooled analysis of EDITION 1 to 3 with 2,496 people found 31 percent less night-time and 14 percent less around-the-clock hypoglycaemia. Severe episodes stayed rare (2.3 versus 2.6 percent).

Does U300 need more units?

Slightly. In EDITION 2 U300 needed about 10 percent more units than U100 for the same reduction of the long-term value. Weight gain was lower with U300.

Does the time of day matter?

In EDITION 4 with 549 people with type 1 diabetes the result was the same in the morning and in the evening, including hypoglycaemia. Fewer night-time episodes than with U100 were only seen there in the first eight weeks, weight gain was lower.

Sorodno

Sorodni izdelki